BD FACSAria™ III SORP Flow Cytometer
——

The BD FACSAria™ III SORP is a flow cytometer equipped with five lasers and 18 detection channels,combining sorting andanalysis functions. Our experimental center has established a mature sortingprocedure and can provide support such as experimental operation training and experimental design.
Manufacturer: BD
Model: FACSAria™ III SORP
Parameters: 5 lasers (355nm, 405nm, 488nm, 561nm, 640nm)
Nozzle configuration: 70, 86, 100μm
Sorting and collection chamber configuration: 2 channels, 4 channels
Detectable channels: See the diagram below
| BD FACSAria™ II SORP Flow Cytometer | ||
| Excitation Laser | Filter | Fluorochrome |
| 355nm | 450/50 | DAPI |
| 585/15 | BUV563 | |
| 730/35 | BUV737 | |
| 405nm | 450/50 | BV421、V450、Pacific Blue |
| 525/40 | BV480、V500、BV510 | |
| 610/20 | BV605 | |
| 670/30 | BV650 | |
| 710/50 | BV711 | |
| 780/60 | BV786 | |
| 488nm | 530/30 | FITC、BB515、Alexa Fluor 488 |
| 695/40 | PerCP、BB700、PerCP-Cy5.5 | |
| 561nm | 585/15 | PE |
| 610/20 | PE-CF594 | |
| 670/30 | PE-Cy5 | |
| 780/60 | PE-Cy7 | |
| 640nm | 660/20 | APC、Alexa Fluor 647 |
| 730/45 | APC-R700、Alexa Fluor 700 | |
| 780/60 | APC-Cy7、APC-H7 | |
Beckman CytoFLEX S flow cytometer
——

The Beckman CytoFLEX S is a flow cytometer equipped with four lasers (405nm, 488nm, 561nm, 638nm) and 13 detection channels. Our experimental center has established a mature cell analysis program and can provide support in theoretical training, experimental operation training, and experimental design.
Model: CytoFLEX S
Parameters: 4 lasers (405nm, 488nm, 561nm, 638nm)
Channel Configuration: See the diagram below
| Beckman CytoFLEX S flow cytometer | ||
| Excitation Laser | Filter | Fluorochrome |
| 405nm | 450/45 | BV421, Pacific Blue. dye V450, eFluor450 |
| 525/40 | BV510, V500, AmCyan, Krome Orange | |
| 610/20 | BV605, Qdot605 | |
| 660/20 | BV650, Qdol655 | |
| 488nm | 525/40 | FITC, Alexa Fluor® 488, CFSE, Fluo-3 |
| 690/50 | PerCP, PerCP-Cy5.5, PC5, PC5.5, PI | |
| 561nm | 585/42 | PE, PI |
| 610/20 | ECD, PE-Texas Red, PE-CF594 | |
| 690/50 | PerCP, PerCP/Cy5.5, PC5, PC5.5, PI | |
| 780/60 | PE/Cy7 | |
| 638nm | 660/20 | APC, Alexa Fluor® 647, eFluor660 |
| 712/25 | Alexa Fluor® 700 | |
| 780/60 | APC/Cy7, APC/Fire750, APC-H7 | |
DAKEWE CytoPeak flow cytometer
——

The DAKEWE CytoPeakT1 is a flow cytometer equipped with three lasers(405nm, 488nm, 638nm) and 14 detection channels. Our experimental center has established a mature cell analysis program and can provide support in theoretical training, experimental operation training, and experimental design.
Manufacturer: DAKEWE
Model: CytoPeak
Parameters: 3 lasers (405nm, 488nm, 640nm)
Channel Configuration: See figure
| DAKEWE CytoPeak flow cytometer | ||
| Excitation Laser | Filter | Fluorochrome |
| 405nm | 440/40 | BV421, Pacific Blue |
| 525/50 | BV510 | |
| 610/20 | BV605 | |
| 660/30 | BV650 | |
| 710/50 | BV711 | |
| 780/60 | BV785 | |
| 488nm | 525/50 | FITC, Alexa Fluor® 488 |
| 585/40 | PE, PI | |
| 610/20 | ECD, PE/Dazzle594, PI | |
| 690/50 | PerCP, Percp/Cy5.5, PI | |
| 780/60 | PE/Cy7 | |
| 561nm | 585/20 | PE,PI |
| 610/20 | ECD, PE/Dazzle594, PI | |
| 690/50 | PE/Cy5, PE/Cy5.5, PI | |
| 780/60 | PE-Cy7 | |
| 638nm | 660/10 | APC, Alexa Fluor® 647 |
| 710/20 | Alexa Fluor®700, Spark Red™ 718 | |
| 780/60 | APC/Cy7, APC/Fire750 | |
Agilent NovoCyte Advanteon Dx Flow Cytometer
——

The Agilent NovoCyte Advanteon Dx is a flow cytometer equipped with three lasers(405nm, 488nm, 640nm) and 14 detection channels. Our experimental center has established mature cell analysis procedures and can provide support in theoretical training, experimental operation training, and experimental design.
Manufacturer: Agilent
Model: NovoCyte Advanteon Dx
Parameters: 3 lasers (405nm, 488nm, 640nm)
Channel Configuration: See attached diagram
| Agilent NovoCyte Advanteon Dx Flow Cytometer | ||
| Excitation Laser | Filter | Fluorochrome |
| 405nm | 445/45 | BV421, Pacifc Blue |
| 525/45 | BV510, V500, AmCyan, Krome Orange | |
| 572/28 | BV570, Pacific Orange | |
| 615/20 | BV605, Qdot605 | |
| 695/40 | BV711, Qdot705 | |
| 780/60 | BV785, Qdot800 | |
| 488nm | 525/40 | FITC, Alexa Fluor® 488, CFSE, Fluo-3 |
| 572/28 | PE, PI | |
| 615/20 | ECD, PE-Texas Red, PE-CF594 | |
| 695/40 | PerCP, PerCP/Cy5.5, PC5, PC5.5, PI | |
| 780/60 | PE/Cy7 | |
| 638nm | 667/30 | APC, Alexa Fluor® 647, eFluor660 |
| 725/40 | Alexa Fluor® 700 | |
| 780/60 | APC/Cy7, APC/Fire750, APC-H7 | |
Cytek NL-3000 Full-Spectrum Flow Cytometer
——

The Cytek® NL-3000 is a flow cytometer equipped with three lasers(405nm, 488nm, 640nm) and 38 detection channels. Our experimental center has established a mature 25-color panel and can provide support in theoretical training, experimental operation training, and experimental design.
Manufacturer: CYTEK®
Model: NL-3000
Parameters: 3 lasers (405nm, 488nm, 640nm)
Spectral capture range: 420-829 nm